YOU ARE HERE:

Home All Vendors BICSI OSP Certification OSP-002

Pass4sure BICSI OSP-002 Dumps

Get ready to pass your exam right away with BICSI OSP-002 Practice Questions. These BICSI OSP-002 PDFs are specially designed to make passing easier without any difficulties!

discount banner
Exam Name:
BICSI Outside Plant Designer (OSP)
Exam Code:
OSP-002
Questions:
169
Update Date
Jul 07, 2025
PDF + Test Engine
$65 $97.5
Test Engine
$55 $82.5
PDF
$45 $67.5

PASS4SURE – BEST PRACTICE QUESTIONS FOR BEST RESULTS!

According to recent global reports, there is a considerable rise in demand for BICSI OSP Certification certified professionals. Every other professional is on the lookout to better their career. That is the reason why hundreds of candidates apply for the BICSI Outside Plant Designer (OSP) Exam every year.

BICSI has topped all other industries in development and progress for the last few years. That’s why they make their OSP-002 Exam complex and up to the standards of day-to-day job tasks. We sensed the need for an accurate and reliable Pass4Sure Dumps PDF and jumped right in to provide a helping hand to struggling professionals.

If you are also one of the hopeful aspirants of OSP Certification certification, consider buying OSP-002 Braindumps to pass your exam with distinction. Our experts are working hard daily to give you the best quality BICSI Outside Plant Designer (OSP) OSP-002 Practice Questions. Hundreds of clients have benefitted from Pass4Sure Question Answers, and you can be next.

Pass4Sure team gives 100% for you so you can give your 100% in the exam. With our help, there is no reason left you couldn’t possibly meet your goals. Free OSP-002 Dumps make passing OSP Certification Exam piece of cake. So, get ready for a glittering IT Career in your near future!

WHY US? – REASONS TO BUY BICSI OSP-002 QUESTION ANSWERS

Pass4Sure offers an all-encompassing Dumps PDF set. It has everything an OSP-002 exam candidate needs to pass with an incredible result. We give you a free demo, discounts, free updates for the first three months, and many more. Anyone who wishes to pass the BICSI Exam in the very first attempt must try Pass4Sure OSP-002 Braindumps.

IT industry can always use a proficient and reliable professional to handle their daily jobs. A professional that is an expert in all required tasks is a much-needed asset to an organization. Employers are looking for professionals like that. And we aim to make you into one of the highest-paid, highly-skilled, and credible professionals. It can be possible with our OSP-002 Practice Questions. Getting OSP Certification certified is not a far-fetched dream anymore.

Our focus is providing ease to our precious customers, and it shows in our dedication. After a long-and-hard data analysis, Pass4Sure came up with the best solution to aid failing BICSI Outside Plant Designer (OSP) candidates. Moreover, we make sure you are not left alone in any step of your training. Our reliable experts stay 24/7 active to help you in your success. With top-class Pass4sure OSP-002 Question Answers, passing the BICSI Outside Plant Designer (OSP) exam is 100% guaranteed.

LET OUR FREE DUMPS BE YOUR BIGGEST ACHIEVEMENT!

Our team has curated the best study materials to ease the process of preparing for IT exams. For example, OSP-002 Free Dumps are designed to reflect your exam pattern and format to offer real-like stimulation. The material is 100% tested and approved to get you the success you crave. Unlike others, we keep you updated on your progress. Your good and bad points are laid before you as they are. So, you can focus on bettering yourself accordingly.

The whole process is easy-peasy. For example, the website interface is user interactive. Plus, Accessing and downloading the BICSI OSP-002 Dumps PDF is a matter of just a few clicks.

Pass4sure gives its customers the best, material created with the help of well-known experts, and Practice Questions draw positive results every single time. The OSP-002 Braindumps are updated daily to avoid any difficulties for customers. The package comes in two different formats to meet different types of clients. PDF for candidates always on the go and online test engine for those who enjoy a real-like experience.

The feedback we receive from our valued customers is proof of our credibility. Our customer care service is always at your beck and call. Leave us an email or a message in the chatbox below, and we will be there for you within seconds.

Pass4sure OSP-002 dumps

BICSI Outside Plant Designer (OSP)

Sample Questions


OSP-002 Sample Question 1


Which punchdown block is more often used with data (Cat 5e/6)?

A. Bix block
B. Krone block
C. 110 block
D. 66 block


ANSWER : C



OSP-002 Sample Question 2


The loss of a fiber optic connector is defined as _____?

A. The calculated loss due to geometric misalignment
B. The loss of the connector mated to another connector
C. One-half the loss of a mated pair of connectors
D. The loss of a statistical sample of connectors


ANSWER : B



OSP-002 Sample Question 3


Which network connection type has the highest bandwidth?

A. Power line
B. UTP
C. Wireless
D. Optical fiber


ANSWER : D



OSP-002 Sample Question 4


What is the installed cable plant from work area outlet jack to the patch panel in the elecom closet called?

A. Permanent link
B. Channel
C. Link cable
D. Patchcord


ANSWER : A



OSP-002 Sample Question 5


___________ should be used to bundle cables since _________.

A. Hook and loop cable ties, tight cable ties can affect cable performance
B. Cable ties tightened with guns, cables should not be allowed to move around
C. Cable ties, loose cables are a safety hazard
D. Rubber bands, they stretch


ANSWER : A



OSP-002 Sample Question 6


\_\_\_\_\_\_\_\_\_\_ is the standard which forms the basis of structured cabling in the US?

A. IEEE 802.3
B. EIA/TIA 568
C. EIA/TIA TR42
D. NEMA 63.1999


ANSWER : B



OSP-002 Sample Question 7


Multiple Response: Identify one or more choices that best complete the statement or answer the question.
Preparing cables for splicing in splice closures requires __________.

A. Leaving the proper length of buffer tubes from the cable entrance in the closure to the splice tray
B. Leaving the proper length of fiber to splice and fit the splice in the splice tray
C. Securing the cable properly at the closure entrance
D. Careful cleaning of all fibers


ANSWER : A,B,C,D



OSP-002 Sample Question 8


What kinds of connection to the cable does a UTP jack typically have?

A. 66 punchdown
B. 110 punchdown
C. Snap-in contacts
D. Solder connections


ANSWER : B



OSP-002 Sample Question 9


What kinds of connection to the cable does a UTP jack typically have?

A. 66 punchdown
B. 110 punchdown
C. Snap-in contacts
D. Solder connections


ANSWER : B



OSP-002 Sample Question 10


What kinds of connection to the cable does a UTP jack typically have?

A. 66 punchdown
B. 110 punchdown
C. Snap-in contacts
D. Solder connections


ANSWER : B



OSP-002 Sample Question 11


___________ should be used to bundle cables since _________.

A. Hook and loop cable ties, tight cable ties can affect cable performance
B. Cable ties tightened with guns, cables should not be allowed to move around
C. Cable ties, loose cables are a safety hazard
D. Rubber bands, they stretch


ANSWER : A



OSP-002 Sample Question 12


Hardware like video cameras designed to run on coax can be used on UTP with a converter device called a \_\_\_\_\_\_\_\_\_.

A. Splitter
B. Balun
C. Adapter
D. TOSLINK


ANSWER : B



OSP-002 Sample Question 13


FDDI and Token Ring networks used a \_\_\_\_\_\_\_\_\_\_\_ architecture.

A. Bus
B. Star
C. Ring
D. Balanced


ANSWER : C



OSP-002 Sample Question 14


Structured cabling standards call for a maximum length of multimode fiber optic cable for backbones of \_\_\_\_\_\_\_\_\_\_.

A. 800 meters
B. 1000 meters
C. 3000 meters
D. 2000 meters


ANSWER : D



OSP-002 Sample Question 15


Multiple Response: Identify one or more choices that best complete the statement or answer the question. Which of the following communications systems typically use fiber optic backbones? (choose all that apply)

A. Telephones
B. CATV
C. Internet
D. Cell Phones


ANSWER : A,B,C,D



OSP-002 Sample Question 16


Which type of dispersion affects singlemode fiber as well as multimode fiber?

A. Modal
B. Differential
C. Chromatic
D. Polarization mode


ANSWER : C



OSP-002 Sample Question 17


Does a jack have the same color code for the pairs as a punchdown block?

A. No
B. Yes
C. Depends on the type and manufacturer of the jack
D. Depends on whether it is T568A, T568B or USOC


ANSWER : A



OSP-002 Sample Question 18


You can keep track of how much cable is left in a box if you ___________.

A. Record on the cable box the beginning distance marked on the cable
B. Read the distance off the cable
C. Weigh the box
D. You can’t


ANSWER : A



OSP-002 Sample Question 19


Loss of a fiber or any fiber in a cable is measured in __________.

A. dB
B. dBm
C. milliwatts


ANSWER : A



OSP-002 Sample Question 20


Most \_\_\_\_\_\_\_\_\_ are designed to allow easy pulling.

A. Cables
B. Cable trays
C. Cable boxes
D. Ropes


ANSWER : C



OSP-002 Sample Question 21


Wireless networks require cables to connect the server, router or hub to the \_\_\_\_\_\_.

A. PC
B. Uplink
C. SNMP
D. AP (Access point)


ANSWER : D



OSP-002 Sample Question 22


What copper cable types are included in the TIA-568 structured cabling standards?

A. UTP (unshielded twisted pair), STP (shielded twisted pair) and coax
B. UTP (unshielded twisted pair) and coax
C. UTP (unshielded twisted pair), ScTP (screened twisted pair) and STP (shielded twisted pair)
D. Any communications cable


ANSWER : C



OSP-002 Sample Question 23


Which punchdown block is more often used with POTS telephone connections?

A. Bix block
B. Krone block
C. 110 block
D. 66 block


ANSWER : D



OSP-002 Sample Question 24


What is the MINIMUM lighting requirement for telecommunications spaces?

A. 50 lux (4.6 foot-candles) of lighting in the horizontal plane and 20 lux (1.9 foot-candles) of lighting in the vertical plane measured at 1 meter (3.28 feet) above the finished floor
B. 200 lux (18.6 foot-candles) of lighting in the horizontal plane and 500 lux (46 footcandles) of lighting in the vertical plane measured at 1 meter (3.28 feet) above the finished floor
C. 500 lux (46 foot-candles) of lighting in the horizontal plane and 200 lux (18.6 footcandles) of lighting in the vertical plane measured at 1 meter (3.28 feet) above the finished floor
D. 500 lux (46 foot-candles) of lighting in the horizontal plane and 500 lux (46 foot-candles) of lighting in the vertical plane measured at 1 meter (3.28 feet) above the finished floor


ANSWER : C



OSP-002 Sample Question 25


The wavelength of light used for most fiber optic systems is in the __________ region and __________ to the human eye.

A. ultraviolet, invisible
B. solar, visible
C. infrared, invisible


ANSWER : C



LOGIN YOUR ACCOUNT




2 Exams Files

10% off

  • Latest and Most Up-todate Dumps
  • Free 3 Months Updates
  • Exam Passing Guarantee
  • Secure Payment
  • Privacy Protection

3 Exams Files

15% off

  • Latest and Most Up-todate Dumps
  • Free 3 Months Updates
  • Exam Passing Guarantee
  • Secure Payment
  • Privacy Protection

5 Exams Files

20% off

  • Latest and Most Up-todate Dumps
  • Free 3 Months Updates
  • Exam Passing Guarantee
  • Secure Payment
  • Privacy Protection

10 Exams Files

25% off

  • Latest and Most Up-todate Dumps
  • Free 3 Months Updates
  • Exam Passing Guarantee
  • Secure Payment
  • Privacy Protection